# Ultrasound of Portal Vein Thrombosis

- Link: https://sifsof.com/clinical-apps/portal-vein-thrombosis/
- Published: 2020-06-12T13:46:14+00:00
- Author: Developer

Portal vein thrombosis is blockage or narrowing of the portal vein (the blood vessel
that brings blood to the liver from the intestines) by a blood clot. The the term
portal venous thrombosis encompasses a broad spectrum of pathological conditions.

**Portal vein thrombosis** may be seen in a variety of clinical contexts, and when
acute can be a life-threatening condition. It is a major cause of non-cirrhotic 
presinusoidal portal hypertension. Portal vein thrombus may be either bland and/
or malignant (i.e. tumor thrombus), and it is a critical finding in liver transplant
candidates, as it precludes transplantation.

Acute thrombosis may be difficult to detect with grey-scale imaging alone, as the
thrombus may be hypoechoic. With time, it becomes more echogenic and easier to identify.
Color Doppler should be able to demonstrate absent flow in the portal vein and even
to detect partial thrombosis, but attention to the Doppler gain and filters is necessary
to avoid color overwrite of partial thrombosis.

## **Which ultrasound scanner is best for portal vein thrombosis diagnosis?**

Color and spectral Doppler are used to evaluate flow characteristics in the portal
and hepatic vessels. A high-frequency linear transducer [SIFULTRAS-3.5](https://sifsof.com/product/linear-handheld-wifi-ultrasound-scanner-10-12-14-mhz-sifultras-3-5/)
is used for PVT diagnosis.

Color Doppler is also useful to help evaluate for tumor thrombus, which will show
internal color vascularity. Bland thrombus, in comparison, is avascular on color
Doppler. The latter is the first-line imaging study for diagnosis of PVT; magnetic
resonance angiography and CT angiography are valid alternatives.

It is much easier to obtain precise information on the abdominal vessels and their
flow characteristics. As a result, PVT is diagnosed with increasing frequency. Important
advances have also been made in the field of hereditary and acquired coagulation
disorders, shedding new light on the potential causes of venous thrombosis.

In the past, thrombosis of the portal vessels was diagnosed with angiography or 
splenoportography. Today, the vessels of the splanchnic district can be accurately
explored with noninvasive diagnostic methods like ultrasound or color Doppler ultrasound.

The sonographic diagnosis of portal vein thrombosis is based on demonstration of
echogenic material that obstructs the lumen of the vessel and the complete or partial
absence of flow in the portal vein or on the presence of collateral circuits that
by-pass the obstructed vessel, the most typical form being the cavernoma, a tangle
of tortuous vessels, irregular in caliber, that includes the vasa vasorum of the
portal vein and the pericholecystic vessels.

 If the obstruction is partial, [color Doppler](https://sifsof.com/product-category/ultrasound-scanner/color-doppler-ultrasound-scanner/)
can reveal areas of the lumen that are patent and/or the presence of some flow downstream
from the thrombus; the complete absence of flow should be confirmed with pulsed 
Doppler.

As cited in [Portal vein thrombosis: Ultrasound imaging](https://www.researchgate.net/publication/305716474_Portal_vein_thrombosis_Ultrasound_imaging)“
the improvement of imaging procedures the number of patients with diagnosed portal
vein thrombosis is increasingly growing. With a negative predictive value of 98%
color Doppler ultrasound is considered as imaging modality of choice in detecting
portal vein thrombosis.”

References: [Portal vein thrombosis](https://radiopaedia.org/articles/portal-vein-thrombosis),
[Portal vein thrombosis: Ultrasound imaging](https://www.researchgate.net/publication/305716474_Portal_vein_thrombosis_Ultrasound_imaging).

![](https://sifsof.com/wp-content/uploads/2020/06/portal-vein-thrombosis-ultrasound-
1.jpg)

 * ![Mini Linear Handheld WiFi Ultrasound Scanner 10-12-14 MHz, SIFULTRAS-3.5 main](
   https://sifsof.com/wp-content/uploads/2019/03/SIFULTRAS-3.5-mini-linear-ultrasound-
   scanner-300x300.jpg)
 * Mini Linear Handheld WiFi Ultrasound Scanner 10-12-14 MHz, SIFULTRAS-3.5
 * ![Linear Wireless Ultrasound Scanner SIFULTRAS-5.34 - Color Doppler main](https://
   sifsof.com/wp-content/uploads/2018/11/Linear-color-portable-ultrasound-scanner-
   SIFULTRAS-5.34--300x300.jpg)
 * Linear Wireless Ultrasound Scanner SIFULTRAS-5.34 – Color Doppler
 * ![Wireless Linear Color Doppler Ultrasound Scanner SIFULTRAS-5.35 main](https://
   sifsof.com/wp-content/uploads/2017/06/H-L-2-300x300.jpg)
 * Wireless Linear Color Doppler Ultrasound Scanner SIFULTRAS-5.35

[launchpad_feedback]

_Disclaimer: Although the information we provide is used by different doctors and
medical staff to perform their procedures and clinical applications, the information
contained in this article is for consideration only. SIFSOF is not responsible neither
for the misuse of the device nor for the wrong or random generalizability of the
device in all clinical applications or procedures mentioned in our articles. Users
must have the proper training and skills to perform the procedure with each ultrasound
scanner device._

_The products mentioned in this article are only for sale to medical staff (doctors,
nurses, certified practitioners, etc.) or to private users assisted by or under 
the supervision of a medical professional. _