Trolley Type Vein Finder SIFVEINSET-1.0
Main Unit SIFVEIN-5.2 + Trolley SIFTROLLEY-2.1
Trolley Type Vein Finder SIFVEINSET-1.0 includes the main unit SIFVEIN-5.2 and the convenient trolley stand SIFTROLLEY-2.1. It is Designed for seamless use in medical procedures, to enables medical staff to locate veins precisely, which in turn improves puncture accuracy during surgeries. Furthermore, with the addition of the bendable, hands-free SIFTROLLEY-2.1, staff can keep their hands free. thereby allowing the trolley-type vein finder to perform optimally as intended.
The SIFTROLLEY-2.1 is a wheeled stand that brings mobility to medical settings. Equipped with the latest hands-free accessories, it is perfect for environments where vein illumination must be readily accessible at the bedside. Its stable base and smooth-rolling wheels make it easy to maneuver, even in tight spaces, making it a preferred trolley-type vein finder. Now, there’s no need to return the IV vein finder to the charging cradle after each use; the device charges securely in the “quick cup” of the SIFTROLLEY-2.1. This innovative feature allows healthcare professionals to assess veins quickly, secure the device, and proceed with venipuncture effortlessly.
IV vein finder SIFVEINSET-1.0 Main unit Features:
The Ultrasound vein finder SIFVEIN-5.2 incorporates advanced optical structure design for clear vein visualization and enhanced recognition. Here are some of its notable features:
- The Vein Finder SIFVEIN-5.2 uses a new type of optical structure design. That can realize the original position projection and improve the vein recognition rate.
- Fully digital image acquisition and display mode.
- Color adjustment: Red/ Green/ White Color Switch Mode.
- Brightness Adjustment Feature: Switch seamlessly between red, green, and white color modes.
- Black and White reverse: Uses black and white inversion to adjust the switching between vein display and background color.
- Depth identification: Provides More Specific Vein Location.
- Child mode Function: The Child Mode Function is designed specifically for pediatric patients, thereby ensuring accurate and gentle care. As a result, healthcare providers can offer the highest level of comfort and precision during procedures for young patients.
By combining technology with functionality, the trolley-type vein finder delivers precision and ease of use. Whether as vein finder, IV vein finder, or vein scanner, the SIFVEIN-5.2 with SIFTROLLEY-2.1 offers unmatched reliability.
Vein scanner Probe SIFVEINSET-1.0 Specifications:
Specifications Of Trolley Type Vein Finder SIFVEINSET-1.0:
Trolley type vein finder SIFVEINSET-1.0 Applications:
The trolley-type vein finder SIFVEINSET-1.0 has a broad range of applications across medical and cosmetic fields, enhancing precision in various procedures. Its versatile design supports professionals in delivering efficient, accurate, and safe treatments. Here are some of its primary clinical uses:
- Injecting Section: Ideal for intern nurses, the IV vein finder simplifies injection processes, particularly for individuals with obesity, small blood vessels, or darker skin tones, where veins are more challenging to locate.
- Cosmetology: Assists in facial procedures such as hyaluronic acid, water light, botulinum toxin, and collagen injections. With the ultrasound vein finder’s accuracy, it helps avoid serious consequences related to injection errors.
- Cardiology: This tool allows for precise vein positioning during procedures such as bypass surgery, where vein dissection is essential.
- Dialysis: The trolley-type vein finder supports real-time blood flow monitoring during hemodialysis, enhancing patient safety and improving procedure outcomes.
- Peripheral Angiography: This vein scanner illuminates peripheral vessels, providing doctors with clear visual support for diagnosing vascular conditions.
Additionally, this versatile device benefits numerous other departments requiring vein observation, such as universities, nursing colleges, and laboratories, making it invaluable for both diagnostic and experimental needs. The infrared vein finder function assists in visualization, making it highly adaptable for any situation where vein observation is essential.
Trolley Type vein finder SIFVEINSET-1.0 Technical Parameters:
The trolley-type vein finder SIFVEINSET-1.0 combines advanced technology with precision imaging, offering adjustable settings to accommodate diverse clinical environments. Below are its detailed technical specifications:
- Imaging Method: Utilizes DLP in-situ projection without lasers, ensuring safe visualization during procedures. This ultrasound vein finder provides clear, non-invasive vein images.
- Maximum Projection Depth: Reaches up to 10 mm in the hand using an intensifier (provided free of charge), and between 3–5 mm for arms and legs, making it a reliable IV vein finder across various anatomical areas.
- Infrared Wavelength: Operates at an 850NM wavelength, aligning with infrared vein finder standards.
- Rated Power: Consumes 25VA power, with a standby duration of over 180 minutes, ensuring reliable use in medical settings.
- Charging and Resolution: Achieves a full charge in 3 hours (off state) and has a high image resolution of 824*480, guaranteeing sharp and clear vein imaging.
- Precision and Brightness: Offers contrapuntal precision within 0.2mm, with adjustable projection brightness up to 1W20 Lumens, enhancing its effectiveness as a vein scanner.
- Optimal Imaging Distance: Functions best within a range of 20-25 cm, while its lightweight host (0.5 kg) allows for easy handling.
- Projection Colors: Switchable white, green, and red light options allow for flexible vein visualization under varying conditions.
- Working Modes: Includes color and brightness adjustment, black-and-white reverse, pause, depth recognition, and a child mode for pediatric care.
- Processor and Operating System: Equipped with an Intel® Atom processor and running on a WIN8.1 operating system, ensuring stable and responsive performance.
- Bracket Options: Available in table or cart models, adaptable to different medical setups, solidifying its reputation as a versatile trolley-type vein finder.
These technical parameters make the trolley-type vein finder a powerful and adaptable tool for medical professionals, providing accurate, customizable vein visualization that can support multiple settings and patient needs.
Trolley Type Vein finder SIFVEINSET-1.0 Advanced Software and Hardware Features:
The trolley-type vein finder SIFVEINSET-1.0 combines state-of-the-art software and hardware technologies, providing medical staff with superior vein visualization and operational stability. Here are its standout features:
-
- Optical Structure Design: Adopting an advanced optical structure, the trolley-type vein finder achieves in-situ projection, significantly enhancing the vein recognition rate and delivering reliable images.
- Image Enhancement Algorithms: Using multiple image enhancement algorithms, this ultrasound vein finder brings even hard-to-detect veins into clear view, making them distinguishable and easy to locate.
- Depth Recognition: By recognizing grayscale variations, the IV vein finder can estimate vein depth, offering depth hints that enhance procedural accuracy.
- Digital Image Processing: This vein scanner employs a complete digital image acquisition, processing, and transmission system to improve the optical machine’s drive circuit. Paired with a high-performance computer, it provides optimal image quality and a high frame rate for real-time viewing.
- Efficient Power Management: An innovative synchronous rectification power management circuit enhances power conversion efficiency while reducing radiation and ripple, making it an effective infrared vein finder for medical use.
- Centralized Heat Dissipation: With a dedicated design for centralized management and heat dissipation, the device maintains operational stability, even over prolonged use periods. This focus on efficient cooling ensures long-lasting performance and reliability in clinical settings.
Vein scanner :
A. Subcutaneous hemorrhage and vessel sealing:
B. Venous sinus and varicosity:
C. Newborn and coronary heart disease:
D. Blood sampling and injection beauty needle:
Vein Viewer Trolley Type SIFVEINSET-1.0 and Phlebotomy
Phlebotomists play a vital role in healthcare, collecting blood samples and units for laboratory tests, transfusions, donations, and research. Human health depends significantly on the precision and professionalism of phlebotomists, as blood samples are essential for diagnosing various medical conditions. These include cancers, diabetes, thyroid disease, allergies, and pregnancy. Moreover, donated blood and platelets collected at blood centers save thousands of lives annually, such as in California. The trolley-type vein finder SIFVEIN-5.2 aids phlebotomists by enhancing accuracy during blood collection, helping to ensure each sample is safely drawn, identified, and preserved for testing or transfusion.
The trolley-type vein finder offers three primary blood collection methods:
- Venipuncture (VP): This is the most common blood collection method, involving a needle placed in a vein, typically at the arm’s bend or back of the hand. The IV vein finder SIFVEIN-5.2 helps locate veins quickly, ensuring a precise and smooth procedure.
- Skin Punctures: This method involves piercing the skin to collect a small blood sample for minimal testing, such as with a finger prick. The ultrasound vein finder makes it easier to locate ideal sites for these minor collections.
- Arterial Blood Gas (ABG) Puncture: Rarely performed, this involves drawing blood from an artery, usually in the wrist, and is commonly done for patients with respiratory conditions. The vein scanner SIFVEIN-5.2 provides accurate vein visualization, supporting phlebotomists in obtaining samples with minimal discomfort for patients.
With its advanced infrared vein finder technology, the SIFVEIN-5.2 ensures efficient and precise blood collection, enhancing patient comfort and improving sample integrity for vital healthcare procedures.
Multi-Function and Effect Display of the Trolley Type
Vein finder SIFVEINSET-1.0:
A. Color adjustable:
The trolley-type vein finder SIFVEINSET-1.0 provides multiple functions to enhance clinical accuracy, making it adaptable to a variety of medical settings. Below are its key features:
- Color Adjustable: Users can switch seamlessly between red, green, and white colors, creating realistic images that support higher clinical accuracy. This feature ensures that the IV vein finder delivers clear, precise visuals suited to different procedural needs.
B. Black and white reverse:
- Black and White Reverse: This function allows the current vein and background colors to be switched, creating a clear contrast that aids in accurate vein positioning. By reversing the colors, the ultrasound vein finder improves visibility, enabling healthcare professionals to make confident judgments.
C. Brightness adjust
Brightness Adjustment: Adjustable brightness settings allow users to modify image intensity, helping to reduce interference from environmental lighting. This adaptability makes the vein scanner reliable across various settings and lighting conditions.
D. Depth recognition:
Depth Recognition: From deep to shallow, 1-3 indicators light up, assisting in identifying the depth of veins. This function provides more detailed vein depth information, enhancing judgment and improving procedure precision.
E. Children mode:
The infrared vein finder SIFVEIN-5.2 includes a specialized children mode, designed to minimize large-area projection interference, making it especially helpful in pediatric care. This mode increases the success rate of venipuncture by focusing only on the necessary area for infants and children.
Certifications:
FDA
CE.
Vein Viewer Trolley Type SIFVEINSET-1.0
(Main Unit SIFVEIN-5.2 + Wheeled stand SIFTROLLEY-2.1)
12 months warranty.
Related Posts :
[fancy_link title=”The use of vein finders in Oncology and Chemotherapy Administration” link=”https://sifsof.com/clinical-apps/the-use-of-vein-finders-in-oncology-and-chemotherapy-administration/” target=”_blank” style=”2″ ] [fancy_link title=”Rhinoplasty” link=”https://sifsof.com/clinical-apps/rhinoplasty/” target=”_blank” style=”2″ ] [fancy_link title=”Vein Viewers Ease The Pain of Elderly with COVID-19″ link=”https://sifsof.com/clinical-apps/vein-finders-ease-the-new-coronavirus-covid-19-elderly-patients-pain/” target=”_blank” style=”2″ ] [fancy_link title=”Vein-Finder-Assisted Vascular Procedures” link=”https://sifsof.com/clinical-apps/vascular-procedures/” target=”_blank” style=”2″ ]