Sale!
, , , , , ,

Vein Viewer Trolley Type SIFVEINSET-1.0

$3,220

Type: Trolley Type vein finder: Vein finder + Mobile Stand ( Trolley) 

Light type: Infrared.

Depth: – Up to 10 mm in the hand with the help of an intensifier in the palm (accessory provided for free)

– 3 – 5 mm for legs and arms.

Best Projection Distance: 20cm~25cm.

Colors: Red, green, white,

Working modes: color adjustment, brightness adjustment, black and white reverse, pause, depth recognition, children mode

Assisting in: IV Contrast, Mesotherapy, Sclerotherapy, Blood Draw, Nasolabial Folds Injection, Botox Injection, Vascular procedures,…

Certification: FDA, CE.

For quantity discounts Please call +1-323 988 5889.

Vein Viewer Trolley Type SIFVEINSET-1.0

Main Unit SIFVEIN-5.2 + Trolley SIFTROLLEY-2.1

 

Vein Viewer Trolley Type SIFVEINSET-1.0 consists of the main unit SIFVEIN-5.2 and the trolley stand SIFTROLLEY-2.1. The SIFVEIN-5.2 ensures medical staff to perform punctures during surgery and other medical procedures accurately and effectively. With the help of the bendable, hands-free SIFTROLLEY-2.1 staff now can have their friends totally free while the Vein Finder is doing what it is meant to.

The SIFTROLLEY-2.1 is a wheeled stand. It the latest hands-free accessories and it is ideal for any medical setting in which vein illumination needs to be brought to the patient, as the stand’s stable base and smooth gliding wheels allow it to be easily maneuvered.

Now there is no need to return the SIFVEIN-5.2 to the charging cradle in between uses; the device charges while it is in the secure “quick cup” of the SIFTROLLEY-2.1. This “quick cup” allows the SIFVEIN-5.2 to be easily placed in the stand after you’ve assessed the vasculature and are ready to perform the venipuncture.

 

        Main unit Features: Vein Viewer Trolley Type SIFVEINSET-1.0

  • The Vein Finder SIFVEIN-5.2 uses a new type of optical structure design. That can realize the original position projection and improve the vein recognition rate.
  • Fully digital image acquisition and display mode.
  • Color adjustment: Red/ Green/ White Color Switch Mode.
  • Brightness Adjustment Feature.
  • Black and White reverse: Uses black and white inversion to adjust the switching between vein display and background color.
  • Depth identification: Provides More Specific Vein Location.
  • Child mode Function.

 

        Specifications Of The Probe: 

Vein Viewer Trolley Type SIFVEINSET-1.0 specification

 

       Specifications Of The Trolley:

 

Vein Viewer Trolley Type SIFVEINSET-1.0 specification of the trolley

       Clinical Application:

  • Injecting Section – Helps intern nurses to complete injections. To solve the problem of injection difficulty for people of obesity, with small blood vessels or too dark skin, etc. whose veins are hard to find.
  • Cosmetology – For basic facial injections of hyaluronic acid, water light, botulinum toxin, collagen, etc. Avoid the serious consequences of injection errors.
  • Cardiology – Precise positioning for dissection of veins that is needed during bypass surgery.
  • Dialysis – Monitors the patient’s real-time blood flow during hemodialysis.
  • Peripheral angiography – lighting peripheral vessels of the patient and helping the doctor diagnose the condition.
  • And more departments that need to observe veins for diagnosis or experiments, in addition to universities, nursing colleges, laboratories, and so on. You can use a vein visualization device to help observe veins for assisted support.

      Technical Parameters:

    Technical Index:

  • Imaging method: DLP in-situ projection, no laser.
  • Maximum projection depth:Up to 10 mm in the hand with the help of an intensifier in the palm (accessory provided for free)Between 3 – 5 mm for legs and arms.
  • Infrared wavelength: 850NM.
  • Rated power: 25VA.
  • Stand-by time: ≥180min.
  • Charging time: 3H(Off state).
  • Image Resolution: 824*480.
  • Contrapuntal precision: ≤ 0.2mm.
  • Projection brightness: 1W20Lumens (adjustable).
  • Optimal imaging distance: 20cm-25cm.
  • Host weight: 0.5KG.
  • Length: 220mm.
  • Frame frequency: > 30 frame/s.
  • Projection color: white/green/ red light can be switched.
  • Working mode: color adjustment, brightness adjustment, black and white reverse, pause, depth recognition, children mode..
  • Processor: Inter ®Atom.
  • Operating environment: WIN8.1 operating system.
  • Bracket: table model / cart model (optional).

   Software and hardware features:

  • Adopt a new type of optical structure design. Realize the in-situ projection and improve the vein recognition rate.
  • Multiple image enhancement algorithm. To make the veins otherwise difficult to distinguish clearly visible.
  • Depth recognition: The depth of the vein can be distinguished and hinted by the recognition of the gray scale.
  • Through the image acquisition, processing, transmission to achieve full digital and improve the drive circuit of the optical machine. Use high-performance computers. It can effectively improve the image quality and increase the frame frequency.
  • By using an innovative synchronous rectification power management circuit to Improve power conversion efficiency and reduce radiation and ripple.
  • Through the structural design of the centralized management and centralized heat dissipation of the heating device. Makes the whole machine dissipation better solved. Which ensures the stability of the machine for long time operation.

       Application Cases:

   A. Subcutaneous hemorrhage and vessel sealing:

Vein Viewer Trolley Type SIFVEINSET-1.0 vein locator

   B. Venous sinus and varicosity:

Vein Viewer Trolley Type SIFVEINSET-1.0 vein detector

    C. Newborn and coronary heart disease:

Vein Viewer Trolley Type SIFVEINSET-1.0 vein locator

   D. Blood sampling and injection beauty needle:

Vein Viewer Trolley Type SIFVEINSET-1.0 vein viewer

    E. Phlebotomy:

Phlebotomists collect blood samples and units for laboratory tests, transfusions, donations, or research. Human health depends, to a large degree, on the precision and professionalism of Phlebotomists. Physicians diagnose major medical conditions based upon blood samples. Including many kinds of cancer, diabetes, thyroid disease, allergies, and pregnancy. In addition, donated blood and platelets collected at blood centers account for thousands of lives saved every year in California. It is the Phlebotomist who must safely collect blood samples. Identify them accurately and preserve them properly until needed for testing or transfusion.

There are three ways to collect blood using the vein finder SIFVEIN -5.2:

  • Venipuncture (VP) is the most common means of collecting a blood specimen. It involves placing a needle in a vein. Typically at the bend of the arm or back of the hand.
  • Further, Skin punctures involve piercing skin tissue. That will bleed to collect a small amount of blood for minimal testing. An example; of a skin puncture would be a finger prick.
  • Furthermore, arterial blood gas puncture (commonly referred to as an ABG) involves drawing blood from an artery. Typically in the wrist. This kind of draw is rare and as a rule done on patients who have a respiratory condition.

Vein Viewer Trolley Type SIFVEINSET-1.0 vein

 

     Multi-function and effect display:

   A.Color adjustable:

Red, green, and white colors can be switched at will. The image is more realistic and the clinical accuracy is more higher.

Vein Viewer Trolley Type SIFVEINSET-1.0 vein finder

   B. Black and white reverse:

Switch the current vein and background color. In order, to make a clear contrast and enhance the vein positioning judgment.

Vein Viewer Trolley Type SIFVEINSET-1.0 pic

   C. Brightness adjust

Change the brightness of the projected image. To reduce the environmental factors.

Vein Viewer Trolley Type SIFVEINSET-1.0 green light

   D. Depth recognition:

From deep to shallow. 1-3 signal were lit up which improve the judgment of the depth of veins.

Vein Viewer Trolley Type SIFVEINSET-1.0 red light

   E. Children mode:

The vein finder SIFVEIN-5.2 children mode is for infants and children. Which can reduce large-area projection interference and improve the success rate of puncture.Vein Viewer Trolley Type SIFVEINSET-1.0 white

Vein Viewer Trolley Type SIFVEINSET-1.0 application

 

       Certifications:

FDA

CE.

sifultras

Vein Viewer Trolley Type SIFVEINSET-1.0

(Main Unit SIFVEIN-5.2 + Wheeled stand SIFTROLLEY-2.1) 

12 months warranty.

 

Related Posts :

[fancy_link title=”The use of vein finders in Oncology and Chemotherapy Administration” link=”https://sifsof.com/clinical-apps/the-use-of-vein-finders-in-oncology-and-chemotherapy-administration/” target=”_blank” style=”2″ ] [fancy_link title=”Rhinoplasty” link=”https://sifsof.com/clinical-apps/rhinoplasty/” target=”_blank” style=”2″ ] [fancy_link title=”Vein Viewers Ease The Pain of Elderly with COVID-19″ link=”https://sifsof.com/clinical-apps/vein-finders-ease-the-new-coronavirus-covid-19-elderly-patients-pain/” target=”_blank” style=”2″ ] [fancy_link title=”Vein-Finder-Assisted Vascular Procedures” link=”https://sifsof.com/clinical-apps/vascular-procedures/” target=”_blank” style=”2″ ] 

Scroll to Top